Skip to content

Following a track on DP causes power issues – DP incident

Comments:

The report finding from the vessel concluded:

  • The initiating event was a sudden increase of propulsion to full ahead.
  • The main cause was attributed to the computer with unexpected thrust allocation.
  • The secondary cause was human factor due to a slow reaction to switch to manual mode.

Considerations from the above event:

  • This is an extremely deepwater operation, although margins are large, DP control is still desirable.
  • The limitation of using DGNSS as the only position reference system should be known and acknowledged by those involved in the operation.
  • From the information available it would seem this could be an operator initiated problem. Chosen settings of gain, corridor limits, rate of turn and speed of the vessel could all have contributed.
  • The operator could have selected the ‘Stop’ function on the DP console to stabilise the situation, instead of selecting joystick.
  • It is important that instructions for switchboard configurations are supplied and followed.
  • The starboard propeller tripped at 100% load; this should not happen.

DP Event

Published: 10 August 2017
Download: IMCA DPE 03/17

Classification:
Submit a Report

The following case studies and observations have been compiled from information received by IMCA. All vessel, client, and operational data has been removed from the narrative to ensure anonymity.

Case studies are not intended as guidance on the safe conduct of operations, but rather to assist vessel managers, DP operators and DP technical crew in appropriately determining how to safely conduct their own operations. Any queries should be directed to IMCA at dpreports@imca-int.com. Members and non-members alike are welcome to contact IMCA if they have experienced DP events which can be shared anonymously with the DP industry.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.