Fuel spray fire
What happened?
The Marine Safety Forum (MSF) have released Safety Alert 18-16, in which a vessel experienced machinery failure which could have resulted in a far more serious outcome. The vessel had been forced to stop operations due to foggy weather. A high-level alarm was sounded on the forward bilge. Investigation of the alarm showed that the forward bilge was full of fuel oil; the fuel was spraying from the port main engine onto the engine room plates.
What were the causes?
Upon further inspection, it was found that the fuel oil secondary filter differential pressure sensor isolating valve on the port main engine had cracked, and this was causing the fuel spray. Approximately 1m3 of fuel was lost.
- The failure of the valve was caused by a combination of engine vibrations and the weight of assembly acting on the male threaded section of the brass valve;
- The pipe arrangement had been altered from the original set up because of pressure fluctuations – this interfered with the proper functioning of the sensor; the MSF notes that the long-term effect of this alteration was perhaps not properly assessed by the manufacturer prior to this alteration.
What actions were taken?
- Replacement of the brass valve fitting with s stainless-steel equivalent;
- Addition of a deflector plate above the valve to prevent future failure and prevent fuel spray from reaching the hot engine.
What lessons were learned?
- Always apply the management of change (MoC) process when implementing changes on board;
- Discussions of the long and short-term consequences of any changes should be had, assessing any potential risks.
The full safety alert can be found on the MSF website.
Members may wish to refer to the following incidents:
Safety Event
Published: 20 July 2018
Download: IMCA SF 15/18
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.