Loss of tunnel thruster – DP undesired event

Comments from the report:

During diving operations in open water, tunnel thruster No. 1 tripped offline.  Investigation showed that the cause was due to tripping of the thruster hydraulic pump because of voltage instability.  The voltage instability was caused by a spike load on an unrelated circuit breaker on the same switchboard which tripped.  Because of the voltage drop on starboard 690V switchboard during the event some of the equipment breakers opened on under voltage:

  • Tunnel Thruster No. 1 due to power drop to hydraulic pump and signal command “External Shutdown” from controller to frequency converter drive.
  • Starboard ER fans.

The vessel maintained position throughout the event.

Considerations of the IMCA Marine DP Committee from the above event:

  • This event highlights how unrelated equipment failure can have an effect on DP system equipment and therefore the vessels redundancy concept and needs to be considered during failure analysis.
  • It is assumed that redundancy was not compromised by the tripping of the tunnel thruster and therefore it was not necessary to initiate a DP amber alert.
  • It is not good practice to have 4 DGNSS selected to the DP controller, this could result in rejecting other selected systems if the DGNSS were to drift due to a common satellite problem.
  • The root cause should have been identified and isolated from the 690v switchboard before the thruster was re-enabled.

DP Event

Published: 18 February 2019
Download: IMCA DPE 01/19

Classification:
Submit a Report

The following case studies and observations have been compiled from information received by IMCA. All vessel, client, and operational data has been removed from the narrative to ensure anonymity.

Case studies are not intended as guidance on the safe conduct of operations, but rather to assist vessel managers, DP operators and DP technical crew in appropriately determining how to safely conduct their own operations. Any queries should be directed to IMCA at dpreports@imca-int.com. Members and non-members alike are welcome to contact IMCA if they have experienced DP events which can be shared anonymously with the DP industry.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.