Loss of one redundant group – DP undesired event

Comments from the report:

A partial blackout of the centre high voltage (HV) switchboard at 11.04am caused by No. 2 generator.  This caused the loss of the 440V distribution board and thrusters No. 3 & 6.  The centre generator No. 1 started and connected onto the switchboard, there was no loss of power to the drill floor as this is fed from both port and starboard HV switchboards.  The power management system worked as expected, investigation found a poor connection to the temperature sensor of No. 2 generator causing the temperature fluctuation.

There was no loss of position.

Considerations of the IMCA Marine DP Committee from the above event:

  • With the loss of one redundant group DP amber alert should have been activated.
  • The system reacted well to the loss of the centre switchboard however it was felt worthwhile to highlight the configuration in this case. The vessel was operating with one generator on each of the three switchboards.  Therefore, it was accepted that if one generator failed then one redundant group would be lost.
  • It is important that DP personnel are fully aware of the situation and recognise that there could be a degree of risk as the switchboard is brought back on line.

DP Event

Published: 18 February 2019
Download: IMCA DPE 01/19

Classification:
Submit a Report

The following case studies and observations have been compiled from information received by IMCA. All vessel, client, and operational data has been removed from the narrative to ensure anonymity.

Case studies are not intended as guidance on the safe conduct of operations, but rather to assist vessel managers, DP operators and DP technical crew in appropriately determining how to safely conduct their own operations. Any queries should be directed to IMCA at dpreports@imca-int.com. Members and non-members alike are welcome to contact IMCA if they have experienced DP events which can be shared anonymously with the DP industry.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.