Container door hinges failure: Container door fell on deck
IMCA has received details of an incident highlighting dangers from the lack of maintenance to container doors.
A container was being opened as illustrated in the two photographs below. As the left hand door was opened the top hinge broke, followed by the second and third hinges, and the door fell onto the deck.
Nobody was struck or injured during this incident.
The cause of the incident was found to be lack of lubrication between the vertical rod and the hinges, which should rotate on the rod. They had become corroded and jammed intermittently and had suffered fatigue due to opening and closing of the door resulting in cracking and eventually failure.
The company has noted the following precautionary measures:
- Container door hinges of this design should be routinely checked every time they come on board for signs of jamming, wear, tear, and lubrication applied accordingly;
- If lubrication and corrective actions are required on board, particularly to hinges in containers, then a non-conformance report should be submitted so that appropriate preventive measures can be taken.
Safety Event
Published: 3 July 2003
Download: IMCA SF 08/03
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.