FMEA – Five Yearly Review
The IMCA Marine DP committee promotes the practice of maintaining an up-to-date DP system FMEA/FMECA. Opportunities to benefit from new guidance and lessons learned may be missed if the FMEA/FMECA document is not periodically refreshed. A neglected DP system FMEA/FMECA may lead to a reduction in robustness, resilience, and single fault tolerance if it is only updated after deficiencies have been identified by a vessel DP Assurance process or after major upgrades are carried out to the vessel’s DP system.
IMO MSC.1/Circ.1580, Guidelines for Vessels and Units with Dynamic Positioning Systems, Chapter 5.1.2 states:
For equipment classes 2 and 3, an FMEA should be carried out. This is a systematic analysis of the systems to the level of detail required to demonstrate that no single failure will cause a loss of position or heading and should verify worst-case failure design intent. This analysis should then be confirmed by FMEA proving trials. The FMEA and FMEA proving trials result should be kept on board and the FMEA should be kept updated so that it remains current.
IMCA M 166, Guidance on Failure Mode Effects Analysis Guidance, Chapter 2.7 Updating of an FMEA states:
The FMEA will become out of date if it is not maintained regularly and systematically, due to changes in operating procedures, modifications to DP hardware and software, to confirm compliance with the latest industry guidance, etc., over the life cycle of the vessel. If this happens, it is likely that another FMEA revision will be incurred later. A systematic FMEA review through the vessel’s life cycle should be an ongoing process which should be formally completed at least once every five years.
To view all information, please download PDF.
IMCA Contact
Richard Purser
Technical Adviser - Marine
Contact
Information Note Details
Published date: 3 February 2022
Information note ID: 1605
Downloads
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.