Lifting chains parted – hydrogen embrittlement
What happened
Three of four lifting chains on a load parted while the load was being lifted. The incident occurred in the last lift of sections of grillage from a vessel involved in project demobilisation. At the time of the incident, the grillage was suspended, above the deck, by approximately 4m. Following a discussion between the Deck Foreman and the Crane Operator, the grillage was slowly lowered down to the deck. There were no injuries.
What went right?
- All the work was conducted in line with established risk assessments and with company lifting procedures;
- All the crew involved had the correct competencies;
- The rigging was only three months in use from purchase;
- The load was well below the SWL (Safe Working Load) of the chain;
- The chain was never deployed subsea and was stored in a rigging locker.
What was the cause?
Analysis by an independent third party, and the chain manufacturer, concluded that hydrogen embrittlement, causing pitting, exacerbated by the tensile load on the internal radius of the links caused surface corrosion cracking, leading to internal branch cracking and failure.
Actions taken
The rigging was changed from a four-way bridle arrangement to slings and shackles, and the lift was completed safely.
Lessons and further information
Safety Event
Published: 21 June 2023
Download: IMCA SF 15/23
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.