Skip to content

Emergency musters and drills

Two of our members have shared recent events relating to emergency drills and musters.

Incident 1 – Emergency button stuck

During an emergency drill, it was found that the General Emergency alarm on the bridge was delayed whilst being activated.

Further investigation revealed that dedicated Emergency button was stuck, and it failed to perform its function in a timely way during the drill.

Lessons

  • Check: could your emergency alarm buttons be stuck or seized? When was the last time anyone actually pressed the fire alarm button?

Members may wish to refer to:

Incident 2 – Near Miss – Smoke at muster station

A fire alarm was set off on the port side muster station where there was a smoking area. An AB and the 2nd Mate were sent to investigate what was going on. On arrival at the muster station there was dense smoke coming from the ashtray stand. The ashtray was opened, and a smouldering paper cup was found, along with recently discarded cigarette butts.

The smoker had, instead of bringing the cup to the dedicated waste bin which is just 10 metres away, just opened the standing ashtray and dumped the paper cup together with the still burning cigarette butt and closed it. This action caused smouldering and a small fire and could have developed into a much more serious situation.

What went wrong

  • Personal negligence and not following basic rules;
  • In other circumstances and conditions such negligence could have led to a more serious fire.

Members may wish to refer to:


IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.