Failure to calibrate MRU led to near-miss

A member has reported an incident in which a vessel crane made an uncontrolled payout of approximately 27 metres of winch wire. During crane operations to relocate an anode skid the winch began paying out for no apparen’t reason. The payout occurred when changeover was taking place between auto-tension and active heave modes. This should have allowed the crane to lift the skid in a controlled manner. There were no injuries or damage to assets, but the incident was classified as a high potential near miss.

Our member’s investigation established that the motion reference unit (MRU) housed within the crane had not been calibrated since it was installed in 2008. This had led to incorrect readings from the crane computer system. The calibration had been omitted owing to a changeover in companies responsible for the MRU and a lapse in the onboard planned maintenance system.

The MRU was landed for calibration and it was noted that there was a relatively high offset on the heave signal from the MRU. The decision was then taken to change out the MRU for a calibrated spare.

Following this incident our member decided to carry out a gap analysis of the planned maintenance system of the crane and all other major components in safety critical equipment onboard the vessel against the possibility of similar lapses.

Safety Event

Published: 15 December 2010
Download: IMCA SF 08/10

IMCA Safety Flashes
Submit a Report

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.