Acetylene quad fire on quayside
What happened
A member reports an acetylene gas quad fire which occurred on the quayside. No injuries occurred during the event. The incident occurred during a project vessel demobilisation when sub-contracted welders were being employed to remove sea-fastenings. Both the oxygen and acetylene gases were supplied via 2 x 16 cylinder gas quads sited on the quayside. The vessel was berthed starboard side to, and gas hoses were run from the quads over the bulwark and onto the main deck.


At 16:10 the firewatcher noticed fire coming from the top of the acetylene cylinders and informed the vessel bridge. The marine crew immediately contacted the local fire bridge and mustered all the crew into the galley. The local fire brigade arrived and applied water for approx. 10 minutes before pulling back to a safe distance of 300 meters allowing the acetylene quad to steadily burn.
At 19:00 the emergency services took the decision to use police marksmen to puncture the cylinders by shooting at them to aid the release of gas. 12 shots were fired resulting in 6 of the cylinders being punctured.
At 20:15, on recommendation from the emergency services, all non-essential personnel were evacuated via the Port lifeboat and transferred to a rescue boat and then taken ashore to a safe location for the night. The acetylene quad was allowed to burn off through the night and following further cooling with water the quad was lowered into the sea to bring it to ambient temperature. The quad is currently available for further investigation.
What were the causes?
This incident is currently under investigation – no causes are discerned at present.
The local fire brigade employed a 300 meter exclusion zone; it should be noted that the vessel was unable to move away from the quayside due to a safety exclusion zone. The situation was managed by emergency services working closely with the vessel Master.
However the following preliminary and positive findings were identified – what went right.
- The firewatchers monitoring the work on deck raised the alarm quickly;
- The marine crew acted swiftly and decisively contacting the fire brigade and mustering all crew into the galley;
- There was good separation between the oxygen and acetylene quads;
- Both oxygen and acetylene quads were situated approx. three meters away from the vessel.
Actions
- Ensure thorough pre-use inspections are performed on all oxygen/acetylene equipment;
- Ensure there is an appropriate storage area for gas quads on the quayside;
- Check carefully, your emergency response procedures for gas cylinder and gas quad fires.
Members may wish to refer to:
Safety Event
Published: 30 July 2021
Download: IMCA SF 21/21
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.