Air hose connection failure
What happened
An air supply hose on an air-driven tugger winch snapped out under pressure from the cam lock adapter. A main deck air-driven tugger winch supplied through a 5cm air hose with a nominal pressure of 8 bar was connected by a cam lock coupling to the winch. This arrangement had been in place for several months. Shortly after using the winch the supply hose ejected from the cam lock adapter.

What went right
When the crew heard the noise from the air in the tugger winch area, the air supply to the tugger was immediately turned off. There were no crew members nearby; no-one was injured.
What went wrong
- The wrong type of adapter had been installed on the air hose. Why this was, could not be determined;
- Investigators assumed that the final check to ensure that the work equipment could be operated safely had been not performed properly, since a pre-use visual check should have highlighted the issue;
- The “male thread” adapter was inserted inside the hose and had been tightened by a hose clamp using a “homemade” connection;
- Whip checks, also known as safety whiplash arresters, to prevent serious injury from hose or coupling failure were in place, but not installed correctly;
- A company internal safe use of work equipment assessment checklist had not been used and filled in as required;
- There was inadequate maintenance, control and supervision on materials and equipment used.
Actions taken
- The crew installed the correct type of coupling as an immediate corrective measure;
- Install “hose barb” type cam lock adapters according to the manufacturer hose couplings and accessories specifications;
- Always use whip checks at each hose connection and from equipment to hose to prevent serious injury from a hose or coupling failure;
- Ensure regular, adequately resourced, and planned maintenance of equipment;
- Re-emphasise the hazards of stored pressure.
Members may wish to refer to:
Safety Event
Published: 9 February 2023
Download: IMCA SF 04/23
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.