Airline coupling failure
We have received the following report of an incident which occurred during internal cleaning operations in a produced water de-gasser which was being undertaken by two contract cleaners. This vessel had been open for over a week and forced extraction was in place to ensure that fresh air was being drawn in. In line with normal operating procedures the two cleaners were working under air from a breathing apparatus air line unit fed from a breathing apparatus compressor. During the operation a coupling on the air line parted, terminating the primary source of air supply. The problem was immediately recognised by the vessel entry control personnel and both cleaners immediately opened the air supply from their personal secondary supply and withdrew from the vessel to a place of safety.
The inventory of breathing apparatus (BA) air hoses was collected together for inspection and on cursory inspection the male and female connections looked identical on all hoses. The inspection data, certificates and equipment register also did not indicate any difference between the types of hose.
However, on closer inspection the male fitting indicated a slight difference (see below) which appears to prevent satisfactory connection with the female fitting. The pictures below indicate the difference in the appearance of the made up joints. Both joints hold when tested by hand on initial set up, but the dissimilar tubing fitting is not secure if the tubing is flexed, indicating it does not make a tight/locked connection on the make up.



The following key lessons have been noted:
- Male connections were not stabbing fully into the female connection because of the slight differences in the design of the male connectors;
- Back up air systems worked correctly;
- Safety procedures were complied with.
The company involved has made the following recommendations:
- A system is to be put in place to record that equipment has been fully checked each day before being used on a worksite, to include a supervisor’s signature;
- The contractor is to establish how it was that it was supplied with hoses with ‘mixed’ fittings with the project equipment;
- A new set of compatible hoses has been requested of the contractor.
Safety Event
Published: 1 September 2003
Download: IMCA SF 11/03
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.