Bow thruster room flooded during fresh water transfer operation
What happened?
A vessel’s bow thruster room was flooded during fresh water transfer operations. The plan was to complete receiving fresh water in Tank No. 2 Centre first before moving to simultaneously fill Tank No. 1 Port & Tank No. 1 Starboard, while ensuring using soundings that neither tank was overfilled.
The Duty Motorman (about to end his shift) stopped receiving water into Tank No. 2 Centre believing that it had filled up, and transferred the supply to tanks No. 1 Port & Tank No. 1 Starboard as per the agreed plan.
The incoming Duty Engine Cadet sounded Tank No.2 Centre and realized that it was not yet full. This prompted him to stop and remove the transfer hose from Tank No.1 Port and returned the supply to Tank No.2 Centre. This tank had its sounding pipe linked to the bow thruster room.
Consequently, fresh water flooded the bow thruster room via the sounding pipe which was not locked, to the extent that the generator in the bow thruster room was submerged to about 2/3 of its height.
What went wrong?
- The sounding pipe of Tank No. 2 Centre was not closed (this was the sounding pipe linked to the bow thruster room);
- There was no adequate risk assessment of the fresh water transfer operation. There was no toolbox talk or discussion with the crew of the operation or the risks involved;
- The bilge emergency alarm was neglected by the Duty Engine Cadet;
- The emergency response plan was not followed during this incident.
What were the causes?
- Negligent watch-keeping practice;
- Poor supervision of task;
- Poor handover or shift change procedures;
Lessons learnt
- Requirement for 24/7 watch-keeping in the engine room;
- Better handling of shift change and handover processes;
- Better supervision required particularly of trainee (Cadet) personnel;
Deeper crew understanding of emergency response safety drills particularly for bow thruster flooding.
Members may wish to refer to the following incident:
- Water ingress to bow thruster space
- July 2010 – very similar incident: Some “Key Issues” highlighted at that time:
- Failure of basic watch-keeping practices;
- Lack of understanding of Chief Engineer’s Standing Orders
- July 2010 – very similar incident: Some “Key Issues” highlighted at that time:
Safety Event
Published: 15 December 2017
Download: IMCA SF 31/17
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.