Broken Chinese Finger
What happened
During a reeving operation of the forward crane auxiliary hoist, there was a failure of a “Chinese Finger” between the messenger wire and auxiliary hoist wire. About 6m before reaching the trolley sheave, the Chinese Finger broke, resulting in the auxiliary hoist wire falling down into the cargo hold. The messenger wire fell on the main deck below the crane trolley.
What went right
No-one was nearby where anything landed. There were no injuries.
What went wrong
- The Chinese Finger parted due to direct contact between the sharp edge of the Auxiliary Hoist Wire and the Chinese Finger itself;
- The Chinese Finger could not withstand the applied tension endured during the reeving works;
- The point of contact between the Auxiliary hoist wire and Chinese Finger was too sharp resulting in a point load;
- The Auxiliary hoist dead-end was not tapered and by this created a sharp edge at the extreme end of the wire;
- There was a lack of awareness of this aspect of the use of the Chinese Finger.
Members may wish to refer to:
Safety Event
Published: 14 July 2022
Download: IMCA SF 17/22
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.