Confined space entry: person overcome by fumes and rendered unconscious

What happened?
Three crew members on a vessel were tasked with opening a sewage tank inspection hatch to check the condition of a faulty sensor. The hatch was subsequently removed to facilitate cleaning of the sensor, with one individual standing on a fixed rack to gain access. During the task, that individual was overcome by a concentrated plume of Hydrogen Sulphide (H2S) from the tank, causing him to become unconscious and fall to the deck. He was unconscious for around 90 seconds and suffered minor cuts and bruises to his right hand.

What went wrong?
- Safe systems of work were not followed:
- there was a failure to identify potential hazardous gases as part of the risk assessment
- there was non-adherence to the permit to work (PTW) procedure
- there were inadequate working at height controls
- there was an inadequate tool box talk;
- The manufacturer’s instructions for opening the inspection tank were not followed. In particular, there was no check for potentially hazardous gases;
- The sewage treatment plant had not been operated and maintained in line with manufacturer’s instructions, which led to the build-up of Hydrogen Sulphide.
What actions were taken? What lessons were learned?
- Ensure safe systems of work are followed for all maintenance activities including adherence to the PTW, task risk assessment, toolbox talk (TBT), working at height and associated procedures where applicable;
- Before using or maintaining equipment, ensure that all relevant personnel are familiar with the operation, required maintenance activities, associated risks and required safety controls as defined by the manufacturer’s instructions;
- Ensure that workers tasked with the operation and maintenance of sewage treatment plant are made aware of the potential for H2S, the risks associated, the required control measures including the requirement for breathing apparatus if there is potential for H2S release;
- Re-iterate to all workers that they have a responsibility to stop the job if during the work:
- circumstances change and present new additional risks
- they feel uncomfortable or unsafe or are unsure of the planned task.
Members may wish to refer to:
Safety Event
Published: 28 January 2019
Download: IMCA SF 01/19
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.