Crew Transfer Vessel (CTV) hit protruding scaffolding on a supply vessel
What happened?
During transfer of crew to an Offshore Supply Vessel (OSV) at anchor, a Crew Transfer Vessel (CTV) came into contact with protruding scaffolding on the OSV, causing minor damage to a railing on the CTV. This was the fifth such transfer of personnel without incident; the Master was aware of the protruding scaffolding. The fifth time, during manoeuvring the CTV stern towards the OSV, the CTV contacted the OSV protruding scaffolding, causing minor damage. There were no injuries. The Master of the CTV under-estimated both how far the scaffolding protruded and how the OSV would swing round whilst at anchor.

What went wrong?
- Task seen as routine: the CTV Master and crew had carried out multiple passenger transfers in similar conditions on several occasions. Crew members did not see this as an imminent hazard and no changes were made to their approach, no need was seen for additional safety measure at that point in time;
- The existing risk assessment did not address the protruding scaffolding nor the risk of the OSV swinging round whilst at anchor.
Lessons
- Greater account should have been taken of the repair works requiring protruding scaffolding. A more comprehensive risk assessment was required, covering protruding objects and covering the potential for continuous swing on an anchored vessel.
Members may wish to refer to:
Safety Event
Published: 27 February 2024
Download: IMCA SF 05/24
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.