Dropped Object – Steel deck plate falls from pipelay tower
What happened
A large steel deck plate fell 9m from a pipelay tower to deck. The incident occurred on a vessel in dry dock, during which testing and inspection of the pipelay tower was taking place. A rope access technician stood on one of the steel deck plates located around the mid centralisers. The bolts securing the deck plate failed resulting in the deck plate upending and then falling to the deck below. The area below had been barriered off before work started. No-one was hurt. On inspection it was noticed that the deck plate fixings were heavily corroded, with three of the four securing bolts providing no support.
What went wrong


- This deck plate and others found were not part of the original pipelay tower structure, nor on any vessel drawings;
- No change management or design engineering was carried out;
- Incorrect size and material grade of bolts were used;
- The deck plate was only supported on the rear section, and no support bracket had been installed underneath the plate where the technician stood;
What went right
- The task was being controlled under a Permit to Work complete with a task specific risk assessment;
- There was effective barrier management in place preventing persons from entering the Drop Zone;
- Good working at height practices were being used by the work party.
Actions
- Ensure all gratings, steel deck plates and their fixings installed at height are inspected as part of a routine inspection program;
- Ensure equipment modifications are controlled through the change management process.

Members may wish to refer to:
- Pro-active intervention prevented high potential dropped objects
- Dropped wooden block in conductor support frame [changes were made that were not captured in procedures]
- Lost time injury (LTI): loose grating fell from crane, a man fell through and was injured
Safety Event
Published: 30 March 2021
Download: IMCA SF 09/21
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.