Dropped object – wooden packing block

What happened

During pipelaying operations, a wooden packing block (approx. 1kg) became attached to the pipe whilst spooling off the reel. It crossed the main deck and entered the pipelay tower with the pipe, where it became detached and fell more than 10m through the lay system before landing on the workstation floor. There were no injuries.

Our member noted that this was the first time a packing block had breached all barriers in the tower and landed in the workstation. Falling wooden blocks are expected during spooling operations, often falling into the spooler reeler basin. It is a known hazard, therefore operations are supported by risk controls such as barrier management and other safeguards.

Workstation showing dropped impact point
Gap in the mesh platform that the block fell through

What was the cause

Investigation revealed:

  • The dropped object (wooden packing block), used for crossover packing on the spooler reel, had compressed into the parent coating of the pipe. It was thought that this was the mechanism that has transported the block on the pipe and into the lay system;
  • The DROPS barriers on the workstation were inadequate to prevent a wooden block getting through the gap around the annulus of the pipe. The drops barrier is also susceptible to movement from pipe deflection without retracting with the pipe, and this could potentially widen the gap around the pipe. The dropped object passed through this gap and landed on the workstation floor. Had the barrier been suitable to restrict the size of the smallest packing block the incident would have been prevented.

Actions suggested

  • Ensure all barriers are sufficient for the activities you are conducting;
  • Ensure specific barriers (as in this  case, around the pipe) are designed to minimise any gap to prevent the passing of potential dropped objects, whilst still allowing operations to proceed in a timely way;
  • Ensure, so far as is possible, that there are no personnel in high risk/drops work areas;
  • Be aware of risk normalisation and becoming accustomed to seeing unnecessarily dangerous situations in your workplace. Tolerating small defects or gaps in risk control can lead to major incidents;
  • Consider new technologies available such as artificial intelligence using CCTV and alarms.

Members may wish to refer to:

Safety Event

Published: 11 November 2024
Download: IMCA SF 22/24

Relevant life-saving rules:
IMCA Safety Flashes
Submit a Report

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.