Exploding diffuser
During testing and operation of a bell blow down valve, a sintered bronze silencer/diffuser blew apart. Due to extensive fragmentation of the diffuser it has been impossible to determine the reason for this incident, but it is thought to have been caused by a build up of debris within the unit, and possible impact damage during normal use.
The contractor has recommended the following routine should be included in the Planned Maintenance System for the silencer/diffuser.
- Strip down assembly
- Remove deposits using a soft wire brush
- Treat components in an active ultrasonic bath with a suitable solvent to remove rust, corrosion, scale and tarnish until visibly clean
- Dry component using diving quality air
- Reassemble, install and test the assembly.
Safety Event
Published: 1 September 1998
Download: IMCA SF 04/98
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.