Explosion in ballast tank causing loss of life
IMCA has received a report of an incident wherein during a repair job in a pre-load tank (ballast tank) onboard an oil rig at a repair yard, an explosion occurred in the tank. The oil rig was undergoing extensive repairs.
Repair workers using oxy-acetylene torches inside the pre-load tank, had shut the gas torch valves down and left the tank for their break. After their break, when they entered the tank again to continue the job, there was an explosion as soon as they ignited the gas torch.
Two workers were seriously burned and hospitalized. One of them subsequently died in hospital.
The most probable cause of the explosion was ignition of gas coming from the gas torch. On investigation, it was found that the valve on the gas torch was not tight, hence gas had accumulated inside the tank during the break, as there was no proper ventilation of the tank.
The following lessons may be drawn from the incident:
- The conditions for the validity of the issued hot work certificate may change quickly during a work shift and need frequent follow-up;
- Continuous proper ventilation is vital for work carried out in any enclosed space. In this case this would have avoided or reduced the accumulation of gas causing the explosion;
- Gas equipment, including hoses, should be well maintained, so as to perform as desired;
- While temporarily leaving a work place, appropriate precautions should be taken. In this case, the main gas cylinder valves should have been closed and/or equipment removed from the tank.
Safety Event
Published: 31 October 2005
Download: IMCA SF 10/05
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.