Skip to content

Failed nipple on bolt tensioning jack

A member has reported an incident in which a nipple failed on a bolt tensioning jack. A diver was carrying out bolt tensioning on a 24″ pipeline being connected to a pipeline end manifold (PLEM) flange when the nipple flew out of the jack whilst the system was pressurised and hit the diver. There were no injuries.

On investigation it was noted that an incorrect bolt tensioning jack assembly had taken place when a nipple intended for the interconnecting whips had been installed instead of the recommended correct one. The difference in thread size is quite minimal but can be easily identified visually by the different size orifice. Whenever the incorrect nipple comes loose through constant utilisation, this difference is sufficient for it to be forced out when hydraulic pressure is applied to the system.

It is recommended that all nipples on used bolt tensioning jacks/interconnecting whips should be removed and visually checked to ensure that the correct fitting is in place, and replaced as necessary, followed by a maximum system pressure test.

Nipple shown loose
Nipple shown loose
Correct adapter
Correct adapter

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.