Failure of first stage regulator low pressure (LP) blanking cap
What happened
During a dive, a leak was noted coming from the first stage of diver #2’s regulator on the bail out bottle. Further inspection identified that the low-pressure port blanking cap was found to have failed. The dive was terminated, the divers recovered safely, and the regulator was removed from service.
During the investigation of the regulator there were no signs of damage to the body or any of the associated hoses, fittings or the gauge. The regulator was within its recommended annual service period.
The regulator manufacturer was contacted regarding the shelf life of the blanking screws and recommended O-ring replacements.


Actions
The following actions and recommendations are deemed necessary to manage the risk associated with 1st stage regulator blanking caps.
- Immediate actions:
- Manufacturers recommendations
- O-rings to be replaced at each service or every two years
- Confirm torque settings of 2N to be applied to all blanking caps
- Diving Contractors actions
- Replace all blanking caps and O-rings on existing in service 1st stage regulators;
- Update work orders to confirm torque settings of 2N to be applied to all blanking caps;
- Manufacturers recommendations
- Further actions:
- Release as IMCA safety flash;
- Identify and assess condition of all 1st stage regulators that have been in service in excess of 10 years for possible replacement.
Members may wish to refer to:
Safety Event
Published: 8 November 2021
Download: IMCA SF 30/21
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.