Failure of life rafts during servicing
A member has reported an incident in which four life rafts sent ashore for annual servicing had to be condemned and replaced. The rafts had been serviced by a sub-contractor in the previous year and no defects were noted. Subsequently it was found that that sub-contractor had lost its license and certification as a life rafting testing station.
The following defects were discovered:
- The four rafts were found to be suffering from water ingress and corrosion;
- Severe oxidation was found on 20% of the buoyancy chambers, moderate oxidation on 10% of the total area and 35% of the canopy;
- On one raft the protective cover was missing from the inflation cylinder valve and the inflation tube was highly oxidised;
- When the International Maritime Organization (IMO) inflation test was carried out, leaks were observed and the buoyancy chambers burst near the connections of the survival pack and connections to the inflation cylinders;
The rafts would not have worked in the event of an emergency, potentially leaving the vessel crew with no means of escape.
The following recommendations were made:
- All life-saving equipment should be inspected closely following shore-side servicing to verify that the servicing indicated has been properly and thoroughly carried out. Some clear pointers to assist in this process could be:
- Life raft sealing bands show signs of having been replaced
- Evidence of talcum powder on exposed runner of life rafts indicates that the raft was opened and additional talcum powder was applied during repacking
- Service labels updated on life raft wallet.
Safety Event
Published: 14 July 2010
Download: IMCA SF 04/10
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.