Failure of self-righting frame on Fast Rescue Craft (FRC)
What happened?
During a routine rescue drill the self-righting frame assembly fell off the Fast Rescue Craft (FRC) into the water while the FRC was transiting at approximately 15 knots. The self-righting frame was recovered by the FRC crew and returned to the vessel, where the cause of failure identified, and repairs completed.



What went right
- The hazards and risks of the rescue drill had been identified and discussed in the Toolbox talk with all personnel involved;
- Appropriate protocol was followed, and Bridge crew were kept in communication throughout the recovery operation;
- The FRC was repaired promptly to Original Equipment Manufacturer (OEM) specification.
What went wrong
- A third-party inspection of the FRC had been completed two months before the incident. The inspection required only a visual check of the self-righting frame and did not include checking the integrity of the frame securing arrangements;
- Over time the securing arrangements were stressed and showed signs of galvanic corrosion.
What lessons were learnt?
- The integrity of self-righting frames should be periodically inspected. This may involve the removal of the frame;
- Reviewed FRC inspection checklist and procedure to ensure the self-righting frame is periodically removed and inspected.
Members may wish to refer to:
Safety Event
Published: 12 February 2024
Download: IMCA SF 03/24
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.