Fall Protection – Defective Safety Harness
What happened
During equipment recovery operations on the back deck of a vessel, a technician felt something unexpected around the Dorsal ‘D’ ring on the back of his safety harness. Operations were immediately stopped. On inspection, several points of failure were identified on and around the area of the plastic back pad of the harness (see photo).

Findings/Lessons Learned
- Before project mobilisation, the task of inspecting the harnesses was assigned to an untrained short service employee, which was contrary to company requirements;
- There was a failure to adhere to existing internal requirements and control mechanisms associated with the periodic inspection, maintenance and record keeping associated with fall protection equipment systems;
- There was no evidence that a pre-use inspection – as was required by the company – had been completed by the technician before putting on the harness and starting work;
- Wear and tear of the harness and metal components indicated exposure to adverse environmental conditions, suggesting that the harness had not been stored and maintained per the original equipment manufacturer’s instructions.
Actions taken
- Ensure thorough visual inspection of fall protection safety harnesses by an appropriately trained person. Safety harnesses found unfit for service should be quarantined or destroyed;
- Maintain a comprehensive fall protection equipment register;
- Always store fall protection equipment in an environment protected from the elements and in accordance with the original equipment manufacturer’s requirements.
Members may wish to refer to
Safety Event
Published: 12 February 2024
Download: IMCA SF 03/24
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.