Fast Rescue Boat (FRC) comes close to falling off in a dry dock
What happened
During an annual test of an FRC (Fast Rescue Craft) and davit on a vessel in dry dock, the boat tipped forward and collided with a railing while the stern became stuck. During the launch, the engineers powered up the davit and began paying out the wire. However, a lashing line was not removed, causing the forward part of the FRC to collide with a railing while the stern became stuck. Additionally, the hydraulic piping started leaking. The operation was halted; there were no injuries.


What went right
On discovery of the hydraulic leak the operation was promptly halted, and the FRC was secured to prevent further damage.
What went wrong
- In the initial stages of the launch the FRC was still lashed down, causing the forward part of the FRC to collide with a railing while the stern became stuck;
- The hydraulic pipe burst due to abnormal pressure conditions;
- There was a lack of clear procedures and communication during the launch process;
- In particular, insufficient pre-launch checks and communication.
Actions taken
- Risk Assessment: Include comprehensive checks for mechanical and hydraulic systems before launching the FRC;
- Communication: Maintain clear and consistent communication channels between the officer in charge, engineers, and crew members;
- Procedures: Develop and implement detailed procedures for the launch and retrieval of the FRC, ensuring all crew members are trained and aware of their roles.
Members may wish to refer to:
Safety Event
Published: 31 July 2024
Download: IMCA SF 15/24
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.