Fatal accident with lifting appliance
IMCA has received a reports on a fatal incident during a lifting operation. A provisions crane was loading pallets onto a vessel using a pallet fork. After landing a pallet on the deck, the pallet fork was pulled clear and the crane operator moved the crane outward to pick up the next load. During this operation, the crane winch wire snapped. The pallet fork fell onto the deck, landing on a member of the crew, who subsequently died of his injuries.

The company noted the following causes to the incident:
- a malfunctioning or missing upper limit switch’;
- the wire end at the hook side was terminated by means of three incorrectly-applied U-bolt clamps instead of a ferrule and swage (see figures overleaf).
The following lessons were drawn from the incident:
- Limit switches are important safety equipment that should be tested regularly to confirm their proper operation
- Winch wire end terminations should be correctly performed. . Cranes should be inspected before lifting operations, using an approved check-list . Procedures should be established to ensure personnel are properly informed of the hazards involved in crane operations, and do not stand underneath loads


Safety Event
Published: 7 July 2006
Download: IMCA SF 09/06
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.