Fatal diving incident
The Danish Maritime Authority Investigation Board has produced a report regarding a recent fatality which occurred during diving operations. The fatality occurred when a diver was working underwater at approximately 41 metres, and his air supply was cut off due to an unintended squeezing of his umbilical.
Further information is available at dmaib.com/Ulykkesrapporter/MAERSK_TENDER_24072010.pdf
Safety Event
Published: 25 November 2011
Download: IMCA SF 13/11
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.