Finger crushed under Tether Management System (TMS) protection guard
What happened
A worker suffered a crushed finger when the protection guard of a Saab Seaeye TMS8 Tether Management System fell on their finger. The worker was closing and securing the protection guard and lost grip on the guard. The guard fell down and trapped the left ring fingertip between the guard and the TMS frame. Upon removal of the glove it was identified the fingertip was damaged. The injured person went straight to the medic, who verified that the injury warranted hospitalisation, and the injured person was taken to hospital onshore.

What went right
- The injured person received medical help immediately and could be taken ashore for treatment quickly.
What went wrong – what was the cause
- With the two top pins removed the TMS guard can fall down if not safely supported – as when grip is lost;
- It was cold; there was no weather protection – cold hands;
- The worker was keen to complete the task in hand;
- The worker was not wearing the correct type of gloves;
- The task not fully risk accessed; there was no specific procedure/training to follow for guard removal.
Actions
The design of guards and securing method is under review for potential improvements. In the meantime a procedure for safe guard removal and refitting was generated and issued to all TMS8 owners as detailed in the bulletin here and copied below.
Members may wish to refer to:
- Lost time injury (LTI): Finger injury whilst working in engine room [the trainee wiper’s hand slipped from the rope causing sudden drop of the pipe]
- Dropped Object – door detached from TMS during dive



Safety Event
Published: 13 March 2023
Download: IMCA SF 07/23
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.