Fractured finger while handling metal plates
What happened
While working on deck, a crew member suffered a pinch injury to his right hand baby finger, resulting in a distal fracture to the tip of the finger and a significant laceration requiring sutures to the finger above the nail bed.
What went wrong?
Heavy weather had caused damage to welded plates on deck. While manually handling the plate back into position with another crew member, the injured person suffered a pinch injury to his finger which was trapped between the plate and frame. Following a medical review, the vessel headed into port to permit further diagnosis at hospital. An X-ray showed a distal fracture to the tip of the finger and the wound required stitches.

What was the cause?
- The design of the plate did not allow for safe manual handling;
- The installation of the plate had a permanent risk of finger entrapment;
- The risk assessments and toolbox talk used were generic in content and not task specific;
- The JSA used was for hot work only and did not include manual handling at all.
Lessons learned
- Safety by design: the plate was subsequently modified to have a pair of temporary handles to keep fingers away from the pinch points;
- Magnetic lifting handles sourced as a long term solution;
- Take care with generic risk assessments – ensure they are either modified to suit the task, or use a dynamic risk assessment or toolbox talk specifically for a full and thorough review of the task.
- If the task is slow, uncomfortable or inconvenient, can we use the toolbox talk or JSA to better define and understand these areas of risk? Can we remove the risk or reduce its likelihood or severity?
Members may wish to refer to:
Safety Event
Published: 28 February 2022
Download: IMCA SF 05/22
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.