Galley equipment broke free of fastenings during severe weather
A member has reported an incident which occurred during a severe storm, whereby a grill fryer in the galley broke loose from its floor mountings and toppled over. A steward working in the vicinity had a narrow escape when the grill fryer just missed him. There were no injuries.

The company took the following immediate actions:
- The galley was evacuated and the bridge was informed;
- An electrician was called to isolate the grill fryer;
- Following electrical isolation, the grill fryer was made safe by temporary sea-fastening until the weather abated and permanent repairs could be made.
During subsequent investigation, it was discovered that the grill fryer had been very poorly connected to the galley floor during the construction of the vessel. The securing bolts had only been screwed into the tiles and not into the steel of the deck.
The vessel crew subsequently checked all other galley appliances and found that they were all securely bolted to the floor. Once the weather had abated, the crew reinstalled the grill-fryer, ensuring that it was securely mounted on the floor.
Safety Event
Published: 12 March 2007
Download: IMCA SF 02/07
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.