Grit hose parting: Near-miss incident

A member reports that while a diver was working on a grit-blasting operation, the grit hose parted from the coupling connection on deck. No one was injured and nothing was damaged.

The LP compressor was shut down immediately and a safety meeting was conducted onboard to discuss the reasons for the parting and the precautions necessary to prevent reoccurrence.

The company has set out the following checks to be made before use of the equipment:

  • Check the condition of the hose for any physical damage;
  • Check all hose-line clamps (including gun end and compressor end) for tightness, to ensure no inadvertent parting of the hose while in use;
  • All hose connections are to be secured with safety rope to prevent a whiplash effect if parted;
  • Insurance wire is to be fixed on all quick-release ‘Chicago’ couplings to prevent inadvertent parting of couplings while in use;
  • All hose lines are to be anchored/secured with rope to fixed structures, again to prevent a whiplash effect if parted;
  • One person is to be available to man the compressor and blast-pot at all times while work is in progress.

Safety Event

Published: 1 November 2001
Download: IMCA SF 13/01

IMCA Safety Flashes
Submit a Report

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.