Guidewire anchor failure
A member has reported that during subsea operation, the upper part of a guidewire anchor disengaged from the main body of the anchor, resulting in the unintended release of the guidewire.
Upon investigation, it was found that the shear pin, which was secured in the guidewire anchor housing by the use of a setscrew, had become unscrewed (probably due to vibration), allowing the shear pin to drop out.
During interviews, it was also established that on some sites, the shear pin had been removed by force, without the setscrew first being set or unscrewed. This misuse would, in due course, cause damage to and weaken the shear pin.
Action taken:
The manufacturer involved in this instance, as a result of the investigation, has carried out modifications to the outer sleeve on the upper part of the guidewire anchor, to secure the shear pin when the outer sleeve is in the ‘set’ position. Its user manual has also been updated accordingly, emphasising the correct use of the setscrew. The manufacturer is offering the improved guidewire anchor as both a modification kit for existing anchors and as a new product.
The member involved has issued an instruction that only the modified guidewire anchor is to be used in its operations.
Safety Event
Published: 1 April 2002
Download: IMCA SF 03/02
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.