Hand and finger injuries
Given that the previous four events in this Safety Flash are all hand injuries, some of them quite serious, even shocking hand injuries, we pause to reflect for a moment, and to summarise some trends in hand and finger injuries amongst our members in recent times. Hand and finger injuries comprise almost a fifth of the incidents and events submitted by IMCA members just in the last year.

If we look more closely at the most recent ten incidents involving injuries to hands and fingers, some worthwhile conclusions may be drawn from what our members identified as having gone wrong.
Contributory factor | |
Poor or incorrect PPE | 6/10 |
Equipment in use was not adequate | 5/10 |
Lack of awareness of risk or inadequate risk assessment | 5/10 |
Poor spatial awareness – fingers were in the wrong place at the wrong time | 4/10 |
Lack of supervision | 4/10 |
Lack of communication or poor communication | 3/10 |
Procedures were not followed, corners were cut | 2/10 |
Someone could have stopped the job – but didn’t. | 2/10 |
Someone stepped in and helped with a task when they should have stood back | 2/10 |
Additional causal factors included:
- Poor weather/environment or a noisy and stressful environment;
- A focus on getting job done quickly rather than doing it safely;
- Lack of experience or lack of training,
Please be reminded of IMCA safety promotional materials at https://legacy.imca-int.com/store/safety-promotional-materials/ including:
- Hand safety (poster)
- In the line of fire (longer video)
- Line of fire (short three minutes video)
The ten incidents were:
- Hand injury while using manual torque tool
- Hand injury in medical airlock
- Crew member trapped his left index finger in watertight door
- Hand injury from portable grinder
- Finger crushed under Tether Management System (TMS) protection guard
- LTI: finger crushed while moving mobile gantry crane
- LTI: finger injury during davit test
- LTI: fractured finger during anchor handling
- Line of fire LTI: Finger injury during mooring operations
- LTI: Hand injury in galley
Safety Event
Published: 13 July 2023
Download: IMCA SF 17/23
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.