High potential incident – Foot trapped under ram cylinder
What happened
A person almost had his foot crushed by a ram cylinder on a pipeline coating machine. The incident occurred at a spoolbase, during the application of pipe joint coating, using an Injection Moulded Polypropylene (IMPS) unit. This task is conducted by two persons, the IMPS operator, assisted by a helper – the injured person. This person stepped up onto the IMPS unit platform, and his foot became trapped underneath the lowering ram cylinder. He called STOP to the operator who raised the unit to release the trapped foot. The injured person received first aid, but no further treatment was required.

What went wrong
- Safety by design:
- The process is semi-automated, but at the end it requires the helper to step up on to the IMPS platform to access the pipe: the design of the IMPS system is such that it allows access to a hazardous area without adequate controls being in place;
- There was no physical guarding in place to prevent foot placement under cylinder ram;
- Instructions, procedures and risk assessments were not adequate:
- The hazard of moving equipment (the lowering of the moulding unit) was not identified in the operating procedures;
- There was no instruction in the operating procedures regarding access to the IMPS during the operation;
- While generic risks were covered in the relevant Task Risk Assessments, access issues and pinch points had not been considered.
Lessons to learn
This incident highlights the risk of potential entrapment with moving equipment.
- Identify any moving equipment components that pose a risk of entrapment at your worksite and apply suitable controls e.g., guarding, access restrictions or automatic cut-off;
- Ensure personnel are suitably trained and fully familiarised with the safe operation of the equipment before use. This includes a review of safe operating procedures and risk assessments;
- Have a focus on risk perception and consider regular “cold eyes” reviews of work tasks and equipment use.
Members may wish to refer to
Safety Event
Published: 5 September 2022
Download: IMCA SF 20/22
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.