High potential: navigation near offshore wind turbines
What happened
During survey operations, a chartered vessel entered a wind turbine safety zone on two separate occasions whilst attempting to achieve the closest approach line. On the first occasion, the breach was dealt with onboard the vessel with a safety stand down. On the second occasion, the vessel was immediately stood down and instructed to leave the work site until safe control measures (actions) had been established and agreed with the client.

What went wrong
The incident investigation established that the Officer on Watch (OOW) lost situational awareness and turned the wrong way – to port instead of to starboard. Given that the tide was running north to south, the OOW should have changed course to starboard for safe clearance of the wind turbine. Misjudgement resulted in a miscalculation of the vessel track, significantly contributing to the near miss incident. Agreed onboard procedures and standing orders were not followed.
What was the cause?
- Officers while experienced, were new to this vessel. Consequently, the bridge team had not been working together long:
- Whilst the OOW was an experienced seafarer / officer, he was new to the vessel. He was not fully familiar with the manoeuvring characteristics of this vessel at slow speed whilst towing equipment;
- The Captain was also new to the vessel.
- The OOW overlooked the need to notify the Captain when control of the vessel was lost;
- The risks associated with close quarter navigation / working in close proximity to an offshore structure was not fully appreciated by the bridge team – who are responsible for the safe navigation of the vessel;
- The bridge toolbox talk was not properly implemented at shift change.
Corrective Actions Taken / Recommendations
- Further requirement for enhanced bridge watchkeeping standards and voyage / survey route planning during close quarter navigation;
- Shift change toolbox talk and handover was realigned to include more detail and time to focus on confidence, awareness, communication and contingency scenarios;
- Closer assessment and vetting was required for crew competency, experience and suitability by our member and their vessel charter company during the vessel vetting procedure. This was to be checked and rechecked before starting a project.
Members may wish to refer to
Safety Event
Published: 12 February 2024
Download: IMCA SF 03/24
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.