Implosion of chemical tank

What happened?

A chemical tank, partly filled with Monoethylene Glycol (MEG), imploded on the back deck of a vessel, resulting in a spillage of around two cubic metres of MEG to the back deck and to sea, and unrepairable damage to the tank itself. There were no injuries. The tank was a 26 cubic metre tank, containing 10 cubic metres of MEG.

What went wrong

The implosion happened due to a vacuum created in the tank because the MEG was pumped out into a storage reservoir on the vessel during a mobilisation.

  • A 20 cubic metre tank had been planned for and agreed, but a different and larger type of tank, of 26 cubic metre capacity, was actually delivered;
  • The new tank was unfamiliar to the third-party operators and no documentation was available before starting pumping operations. This type of tank requires a manual air inlet valve to be opened on top of the tank, to allow for air inlet and avoid vacuum. Due to lack of knowledge and documentation, this valve was not opened as it should have been, hence creating sufficient vacuum in the tank to cause it to implode five days later.
  • The supplier of the tank and of pre-commissioning services was new to the company;
    • Although the supplier had been audited before the work, the audit did not generate sufficient insight into the capabilities and experience of the supplier;
    • The possible risks arising from fact that the supplier was new were not recognised in the risk assessment;
    • Only a “standard” onboarding/scope familiarisation was done, there was no adaptation specific to new suppliers.
  • The tank type and specification (it was a carbon fibre tank) were unknown to both the third-party operators and the suppliers;
  • The suppliers’ personnel did not inform any company personnel that they were not familiar with this type of tank;
  • The tank was operated without manuals/datasheet reviewed at the time.

Actions taken

  • Increased focus and follow-up of new suppliers, with specific onboarding arrangements to offshore routines and in-depth familiarisation to scope of work;
  • Ensure that operators of equipment are familiarised with equipment specifications and modes of use, including risk assessment and documentation requirements;
  • Ensure that Management of Change (MoC) is properly applied when equipment is changed out, also when it involves third-party equipment.

Members may wish to refer to events involving third parties, or management of subcontractors. Browse to https://legacy.imca-int.com/safety-events/ and enter the appropriate search term in the dialogue box.


IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.