IOGP: Squeezed hand due to unintentional activation of winch
What happened
IOGP has published Safety Alert #336 relating to a squeezed hand due to the unintentional activation of a winch. A crane operator stood by a control panel to operate the mooring winch. On the level below was an auxiliary winch connected to a rope that was hanging over the railing. By mistake, the crane operator activated the lever for the auxiliary winch, and a crewman on the level below saw the rope connected to the auxiliary winch move. He thought the rope was slipping over the railing and grabbed it. At the same time, the crane operator pulled further on the aux winch lever, which resulted in the crewman’s hand being pulled in and squeezed between the railing and the structure.


What went wrong?
- Poor design: the design of the workplace made it challenging for the crane operator to keep an eye on the control panel while operating the winch;
- The risk of unintentional operation of the winch was not identified, and the injured person’s role in the work operation was not sufficiently described in the procedure;
- The injured person lacked part of the required training and did not know that the auxiliary winch could be operated from the control panel.
Lessons learned
- Improve design of workplace to design out risks;
- Disconnect redundant levers;
- Ensure crew are properly trained and competent for the task at hand;
- Ensure the risk of unintentional driving of the winch is captured in risk assessment, toolbox talk etc.
Members may wish to refer to:
- Accidental discharge of bilge water in dry dock
- Life-raft dropped to the jetty [crewmember accidently released the ratchet strap of the wrong raft.]
Safety Event
Published: 14 July 2022
Download: IMCA SF 17/22
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.