Job stopped safely: safe working load limits exceeded
What happened
Work was stopped during the practical evaluation portion of rigger training in an onshore industry. It was discovered that the application of eye-nuts were not consistent with their intended use. The task was to install rigging and lift a something using a 4-leg bridle chain with adjustable length legs. The attachment points, for the 4-leg bridle chain to the load were four machined eye-nuts (see illustration). A student questioned the safe working load limit of the 1/2″ eye-nut, which was assumed to be installed by the manufacturer of the item being lifted. After researching the eye-nut, a note was found accompanied with the load chart stating that the eye-nut installed was “for in-line picks only.” At that point, work was stopped. The rigging plan to be used involved rigging on the eye-nuts at a 60° angle. Not only were the eye-nuts not being used as intended, but additionally when picking with sling-angles, load capacities are reduced, which would have put the eye-nuts above their safe working load limit.
An alternate load was lifted in this case for training purposes.
This incident, though it is not from within the membership, was passed onto IMCA by a member.

What went right
- The instructor of the class had encouraged a “questioning attitude”;
- The student did not assume the manufacturer-supplied eye-nuts were suitable for the task and questioned the rigging plan;
- Work was stopped;
- This was a real-time example of the importance of inspecting and verifying every link in a rigging plan.
Lessons
- Encourage a questioning attitude and a culture where “there are no stupid questions”.
Members may wish to refer to
Safety Event
Published: 16 October 2023
Download: IMCA SF 24/23
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.