Late onset of decompression illness (DCI)
MCA has received a safety notice which provides a good reminder on the subject of decompression illness (DCI). A company has reported that, following an air dive, a diver developed a pain in his arm more than seven hours after decompression. Due to the length of time between the dive and the complaint appearing, it was assumed not to be divingrelated and painkiller medicine was administered. On worsening, two hours later, the diver was recompressed, but his condition did not markedly improve. It is believed that the period of non-recompression allowed the gas bubble(s) in his tissues to expand and cause internal lesions before dissipating. Thus the later therapeutic treatments, designed to dissolve the offending ‘bubbles’, were unsuccessful, as they could not provide relief for existing physical lesions. The company has reminded its personnel that whenever a diver reports complaints which appear consistent with type I and/or type II symptoms, even up to 48 hours following an air or nitrox dive, the divers must be recompressed immediately, in accordance with company DCI treatment procedures. This should take place immediately – before or in parallel with contacting the diving doctor. If the case is DCI, correct action will have been taken. If it is not a DCI, therapeutic recompression will not make things worse.
Safety Event
Published: 1 May 2004
Download: IMCA SF 04/04
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.