Leak in hot water system for saturation divers
What happened
During saturation diving operations between bell runs it was noted that Divers Hot Water Unit #2 had a water leak. The leak was investigated and located, but was found to be in a place with very poor access. There was a small hole in a pipe, which on investigation was found to be a bigger hole under surface corrosion.
The Dive Supervisors and Dive Superintendent were immediately informed about the issue, and diving was suspended due to there being no backup for the remaining Hot Water #1 Unit.
What went wrong
- Due to very limited access, it was not possible to inspect the tank outlet of the 4″ closed circuit pipework;
- External corrosion had over the years completely corroded the 4mm pipe in a very limited area.
What was the cause
- The direct cause: corrosion over many years;
- The root cause: The inaccessible location [for visual inspection] of the pipe.



What action to take?
- Sleeve welded on the leaky area;
- Hot Water Unit #1 was inspected and no defects found;
- Consider wall thickness measurements of old pipes.
Members may wish to refer to the following:
- Hot water fitting failure results in 3m loss of depth in diving bell
- Dropped object near miss – crane boom bumper stop falls off [d.t. corrosion in an inaccessible place]
Safety Event
Published: 9 January 2024
Download: IMCA SF 01/24
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.