Life raft lashing parted in rough weather
What happened
During rough weather on a vessel at sea, the lashing on a life raft gave way due to wear on stitching on the strap eye. The life raft fell into the water and became inflated.
The life raft was recovered; the sea anchor was damaged, other equipment was found intact, but the shell of the raft was lost at sea.



using wire lash strap
What went wrong
- Lashing straps literally affected by “wear and tear” during poor weather condition;
- Inspection of the straps was not part of the vessel planned maintenance system.
Actions
- A “Y strap” wire lashing may be used (see illustration), given the approval of the manufacturer;
- Regular inspections and pre-checks before rough weather;
- Specific inspection of life raft lashings to be added to vessel planned maintenance system (PMS).
IMCA notes that consideration should be given to the possibility of corrosion and degradation, leading to failure of parts due to:
- Long-term exposure to the weather and to the sea air;
- Repeated stresses induced by the movement of the vessel;
- Accumulated damage or stress over very long periods between inspections – years;
- Difficulty in access for inspection.
Members may wish to refer to:
- Failure of life raft securing strap [2020]
- Dropped object near miss – crane boom bumper stop falls off
- Checking of safety helmets [plastic hats do degrade under UV, over time]
Safety Event
Published: 28 January 2022
Download: IMCA SF 03/22
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.