Skip to content

Lifeboat incident as a result of a suspension chain failure

A serious incident occurred during a routine lifeboat operational test, involving the lowering of a vessel lifeboat into the water. A three-man crew boarded the lifeboat, strapped themselves in, and prepared to lower the boat to the embarkation deck using the remote break release wire from within the boat. Just after the davits reached the end of their travel and the boat started to descend, a loud noise was heard and the aft end of the lifeboat broke away from the hook. Shortly afterwards the forward hook broke away from the boat and the lifeboat fell into the water.

The cause of the lifeboat falling was the breaking of the aft hook suspension chain. The action transferred the whole weight of the lifeboat onto the forward hook, which pulled out of the GRP deck under the excess load. The exact cause of the suspension chain failure could not be established but the most probable mode of failure was brittle failure exacerbated by corrosion pitting.

The recommendations arising from the incident included ensuring that suspension links and chain are suitably heat-treated for use in a marine environment.

Safety Event

Published: 1 January 1999
Download: IMCA SF 02/99

IMCA Safety Flashes
Submit a Report

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.