Skip to content

Lifejacket recall – Mullion Compact 150N ISO 12402

The Marine Safety Forum (MSF) has published the following Safety Flash regarding a potential safety concern with the Mullion COMPACT150N ISO 12402 LIFEJACKET, once it is inflated. Mullion has recalled all COMPACTLIFEJACKETS which have been sold since 1 December 2011 if they have a YELLOW valve in the oral inflation tube. See the diagrams in the link below for more details.

The Safety Flash can be downloaded from marinesafetyforum.org/upload-files//safetyalerts/msf-safety-flash-12.38.pdf

Safety Event

Published: 11 October 2012
Download: IMCA SF 10/12

IMCA Safety Flashes
Submit a Report

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.