Load lost from lorry on public road – inadequate securing of cargo
What happened
During the transportation of equipment, a load became free of its single retention strap and fell off a lorry onto a public road. The load fell off while passing a roundabout at low speed. The loads which fell off were stacked on top of each other and included large hoses on a wooden pallet, each load weighing 100kg. The hose was wrapped in plastic for long-term preservation and had become wet and slippery following rain.
There were no people and no other vehicles in the vicinity at the time.

What went wrong
Our member noted the following:
- The securing of the cargo (large hoses) for transportation, was inappropriate and insufficient;
- The available internal information and instructions were not in a format that could be clearly understood, nor was that information suitably communicated;
- “Task seen as routine” – there was some complacency as this was perceived as a simple straightforward task.
Actions taken
- An incident review session was held with the yard team, to better examine, understand and consider some of the human factors that can influence and introduce complacency in routine tasks / activities;
- The internal information and instructions were improved, following industry good practice for frequently transported goods:
- How to transport them;
- What transportation/securing materials to use (e.g. stillages for hoses instead of pallets);
- How to secure them properly. (e.g. minimum number of straps);
- Who is responsible for doing what, and who is responsible for checking and verification.
Members may wish to refer to:
Safety Event
Published: 31 July 2024
Download: IMCA SF 15/24
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.