Lost time injury (LTI): Thumb laceration
A member has reported an incident in which a crew member was injured when a can of enamel spray paint failed under pressure and parted along the seam. The crew member suffered a significant laceration to his right thumb. The incident occurred during a ‘routine’ maintenance when the crew member was about to start painting.
Upon inspection of the can, there were signs of corrosion along the seam of the can, which has caused the can to part unexpectedly under pressure.


Our member’s investigation revealed the following:
- There was noticeable corrosion of the seam of the aerosol can;
- The vessel had been operating in humid tropical climates over the past 12 months, which may have caused more rapid corrosion and deterioration of the aerosol can;
- There was no system in place to monitor receipt of chemicals or the time the chemicals had been on board.
Our member took the following actions:
- Thorough visual inspection of all aerosol cans on board and also fleet wide globally;
- Amended procedures for dealing with chemicals and other substances hazardous to health, to record when chemicals are received on board and set a maximum usage period;
- Reviewed company list of approved chemicals and see if it was practical to reduce number of aerosols used;
Members may wish to review the following similar incidents (key words: aerosol, corrosion, humid):
- Punctured aerosol results in chemical burns
- Lifting rigging on ‘Frog’ personnel transfer capsule (key quote: “corrosion may have been accelerated due to the hot and humid tropical operating environment in which the equipment was deployed”).
Safety Event
Published: 4 April 2014
Download: IMCA SF 04/14
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.