LTI – worker fractured arm during mooring line handling
What happened?
A mooring rope (weighing 2.9kg per metre) hit a crew person and caused a broken arm. The incident occurred as crew were preparing to unmoor and move a barge. The operation was proceeding as planned when one of the forward mooring station winches in use tripped out. The mooring crew at the forward station informed the Chief Officer about the winch tripping, using UHF. The mooring crew at the aft mooring station, on hearing this information, decided to stop the barge by adding an additional coil on the bollard. Whilst one of the crew was attempting to coil the rope on the bollard, due to a sudden increase of tension on the line, control of the rope was lost, and the rope hit the worker on the left forearm causing the injury. The injured person received first aid treatment promptly and was subsequently evacuated by helicopter.

What went wrong
Confusion, because there was a lack of clear communication with no proper instructions during the operation. The radio communication addressing the tripped winch was misunderstood at the aft mooring station as an “ALL STOP” signal. Instructions were given to secure the mooring rope “in slack” by adding another loop into the bollard. However, the barge was already moving and the mooring line came under tension due to that movement. The injured person was in an unsafe position, with his arm in the line of fire.
Lessons and actions taken
- Over-confidence may lead to poor judgement and making mistakes – if in any doubt, follow the instructions;
- Minimize confusion and ensure there are clear and properly understood communications;
- Our member arranged
- Further training on Line of Fire risks;
- Refresher training for marine crew regarding hazards in mooring operation;
- Awareness sessions customized to the role and responsibility of the Team Leaders and Supervisors, addressing the key elements of their duties.
Members may wish to refer to:
Safety Event
Published: 3 October 2023
Download: IMCA SF 23/23
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.