MAIB: “pinkie is no longer perkie”
What happened
The Marine Accident Investigation Branch Safety Digest 2/2022 includes an incident in which a crew member on a large cargo vessel lost part of their finger while passing through a hydraulically operated sliding door to an adjoining machinery space. The door was fitted with a operating lever handle on either side. The crew member used their right hand to operate the lever handle and the door began to open to the right. The crew member walked through the doorway and placed their left hand on the lever handle on the other side, pushing it down once more to continue the operation.

What went wrong
The door opened fully, while the crew member kept their hand on the handle. As the door retracted fully, the crew member’s left hand became trapped between the handle and the doorframe, resulting in the little finger suffering amputation of the fingertip and nail above the first knuckle. It could not be reattached.
The door was not faulty: Subsequent inspection for technical, hydraulic and electrical defects found it to be in good working order.
Lessons learned (MAIB)
- Training: automatic or powered doors are potentially very dangerous. Hydraulic and electric power-operated systems are unforgiving in their closing force and should be treated with respect. Crew should be provided with suitable training on both the safe use of these doors and the dangers of their unsafe operation;
- Procedures: If we go through a powered door often, it is easy to forget the dangers and take shortcuts such as walking through the door before it has fully opened. Previous accidents have sadly resulted in more serious injuries than those suffered in this case, and sometimes death;
- Awareness: Entrapment is a hazard often associated with moving machinery and wariness is the watchword. There should have been no need for the crew member’s hand to remain on the door’s operating lever and this action indicates insufficient knowledge of the system;
- Short cuts: if the operator was attempting to take a shortcut, then a greater understanding of the system would have been required to understand the dangers of doing so. Lack of understanding of how a system will work when shortcuts are taken, and the potential consequences, are a good enough reason not to take short cuts.
Members may wish to refer to:
- Lost time injury (LTI): Finger injury – watertight sliding door (2016)
- Fatal accident involving a horizontal watertight sliding door (2001)
- Line of fire: pinched finger between door and frame
IMCA will bring further reports from this MAIB Safety Digest in the next few Safety Flashes.
Safety Event
Published: 30 November 2022
Download: IMCA SF 27/22
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.