Skip to content

Main ROV lift umbilical parted

A member has reported an incident in which an ROV umbilical parted, resulting in both the tether management system (TMS) and ROV falling to the seabed. The incident occurred during operations, when an ROV was being recovered from a dive using its winch and A-frame. The ROV and TMS were both later successfully recovered from their known position.

Our member’s investigation revealed the following:

  • The TMS and ROV package was raised to the A frame snubber assembly using manual winch control;
  • Before engaging the umbilical termination socket into the latching mechanism, the latch indicator registered closed and the snubber skirt was in the raised position as per operating procedures;
  • As the umbilical termination socket (bullet) was being engaged into the latching mechanism, the umbilical parted;
  • Following the failure of the main umbilical, the TMS and ROV fell from the latch box.

On further investigation of the Launch and Recovery system (LARS), the following observations were noted:

  • The winch was operating on the core of the drum due to an unusually short umbilical (300m). No line-pull limit was set on the winch drum, which would have been appropriate given the ability of this particular winch to pull in excess of the umbilical breaking strength on the core of the drum;
  • One latch was found to be jammed in a partially open position by the mechanical flag indicator which had rotated and fouled on a section of the snubber frame;
  • Both latch indicator proximity switches were found to indicate closed latch positions when the latches were in fact only partially closed. This could give a false indication on the winch remote control;
  • One latch operating pin was found to be bent and the latch did not action smoothly (possibly as a result of the incident).

The causes of the incident were found to be the combined effect of:

  • The unrestricted line pull of the powerful winch with a very short and relatively thin umbilical (7% of drum capacity);
  • The improper functioning of the latches.

Our member noted that “modern deep water active heave compensated winches require high levels of installed power to enable them to successfully compensate for vessel movements, and to safely recover the package from up to 4000m. This capability is normally only required when the package is at depth. During recovery when the package is close to the surface the winch drum is normally quite full and the effective line pull of the winch is greatly reduced. This generally prevents the maximum torque capacity of the winch from being applied to the umbilical when the TMS is being engaged into the latching mechanism. In this case the very short umbilical resulted in the maximum line pull being applied to the umbilical when the package was pulled into the A-frame snubber.”

The following corrective actions were taken:

  • Modified the unique latch mechanism and indicators of this (one-off) LARS to prevent improper function/false readings;
  • Modified procedures to ensure maximum line pull settings are always below the breaking strain of the umbilical.

Members may wish to consider implementing a procedure to check that line pull is below the umbilical breaking strain, and if necessary, consider fitting some form of line pull control. This is particularly important in light of recent trends towards powerful deep water capable winches combined with thinner, lighter umbilicals with a lower breaking strain.

Care should be taken to ensure the line pull of the winch will never exceed the breaking strain of the umbilical, in circumstances which include:

  • a powerful winch;
  • a thin umbilical;
  • short umbilical length.

Members may wish to refer to the following similar incidents (key words: umbilical, ROV, TMS, dropped, parted)


IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.