Skip to content

Mooring incident: mooring line slipped off and snapped back

What happened?

During mooring operations of a cargo barge, a mooring line slipped off the cargo barge bollards, causing it to whip back and hit the attending tug.  The tug was damaged by the mooring rope and control of the barge was lost for a short period, causing a minor collision.  Due to the tension in the mooring lines at the time, the lines whipped back toward the attending tug, striking the tug’s monkey island and resulting in damage to the antenna dome.

As a result of the loss of control, the cargo barge and our member’s vessel came into collision; however, there was no damage.  There was no risk of injury to personnel during the incident.

What went wrong?

  • Incorrect mooring technique and pulling angle;
  • The mooring lines were tied incorrectly to a bollard on the barge. The mooring configuration was not appropriate and allowed the mooring lines to slip off;
  • The cargo barge bollards were angled ‘backward’ as they were designed for towing operations;
  • The ‘attending’ tug had too much slack paid out on the towing bridle, and therefore attempts to abandon berthing operations were compromised.

What actions were taken?  What lessons were learnt?

  • When mooring alongside a vessel, a ‘figure of eight’ mooring pattern should be applied to prevent the mooring lines from slipping off the barge if there is opposing movement possible between the tug and barge;
  • Consider fit for purpose bollard design with appropriate mooring technique when mooring a tug to cargo barge. Marine inspections should take into account bollard design effectiveness for proposed operations;
  • Further training and instruction for marine personnel involved, on mooring techniques and on line of fire positioning around mooring stations;
  • Verify that contingency plans for marine operations are followed and regularly practiced.

Members may wish to refer to:

Safety Event

Published: 23 August 2019
Download: IMCA SF 20/19

Relevant life-saving rules:
IMCA Safety Flashes
Submit a Report

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.